home *** CD-ROM | disk | FTP | other *** search
/ Night Owl 6 / Night Owl's Shareware - PDSI-006 - Night Owl Corp (1990).iso / 001a / haydesc.zip / OPT9600.TXT < prev    next >
Text File  |  1991-09-16  |  11KB  |  248 lines

  1. Smartmodem Optima 9600
  2. Mon  09-16-1991
  3. -----------------------
  4.  
  5. Hayes Smartmodem OPTIMA 9600
  6.  
  7. The Hayes Smartmodem OPTIMA 9600 is the affordable choice for every
  8. high-speed personal communications application including access to
  9. information systems, bulletin boards and corporate host computers.  OPTIMA
  10. 96 includes a complete set of the most advanced CCITT standards and
  11. supports the most frequently-used modem industry technologies.  OPTIMA 96
  12. provides standard CCITT V.32 connectivity for 9600 bps line speeds and
  13. CCITT V.42bis for up to 38,400 bps throughput on the public switched
  14. telephone network.
  15.  
  16. MODULATION
  17.  
  18. CCITT V.32 - Adopted by the CCITT in October 1984, this standard is now
  19. becoming the mainstream business standard for high speed modems,
  20. overtaking CCITT V.22bis.  CCITT V.32 provides high-speed 9600 and 4800
  21. bps communications.  Supports V.32 Automode procedure and EIA/TIA IS-63
  22. for fallback to lower speeds.
  23.  
  24. International Data Transmission Standards - In addition to CCITT V.32
  25. (9600 and 4800 bps) compliance, OPTIMA 96 also supports V.22bis (2400
  26. bps), V.22 (1200bps).
  27.  
  28. Data Transmission Compatibility - OPTIMA 96 also supports communication
  29. with 103 (300 bps) and 212A (1200 bps) modems.
  30.  
  31. ERROR CONTROL
  32.  
  33. CCITT V.42 - Supports standardized, point-to-point error-control
  34. communications using the CCITT V.42 LAPM (Link Access Procedure for
  35. Modems) protocol.  CCITT V.42's alternative protocol provides backward
  36. compatibility with modems using MNP 2-4.
  37.  
  38. DATA COMPRESSION
  39.  
  40. CCITT V.42bis - CCITT V.42bis international data compression standard for
  41. use by modems incorporating the V.42 LAPM error-control standard provides
  42. compression capabilities to 4:1 enabling OPTIMA 96 to achieve throughput
  43. to 38.4 Kbps.
  44.  
  45. MNP 5 - OPTIMA 96 provides a migration path to V.42bis data compression
  46. by supporting backward compatibility with modems using MNP 5 for up to 2:1
  47. compression.
  48.  
  49. TELEPHONE LINE INTERFACE
  50.  
  51. Dial-up Line - Provides pulse or tone dialing out and auto answering for
  52. Public Switched Telephone Network (PSTN) operation.
  53.  
  54. PABX and Business Line Support - OPTIMA 96 operates in a variety of PABX
  55. environments and has selectable features for operation with business
  56. telephone lines.
  57.  
  58.  
  59.  
  60. MODEM CONTROL AND OPERATION
  61.  
  62. Hayes Standard AT Command Set - Full support for this industry standard
  63. enables OPTIMA 96 to operate with the large installed worldwide base of
  64. communications software.
  65.  
  66. Hayes Escape Sequence with Guard Time - Allows the modem to reliably
  67. escape from the on-line mode of operation (receiving/transmitting data) to
  68. the command mode (interpreting the Hayes Standard AT Command Set) without
  69. being accidentally triggered by transmitted data.  U.S. Patent 4,549,302
  70. was granted to Hayes on October 22, 1985.
  71.  
  72. Automatic Feature Negotiation -  OPTIMA 96 automatically negotiates with
  73. other modems to analyze all features available (modulation, error-control,
  74. data compression, etc.) to establish the most efficient communications
  75. session.  This powerful capability is implemented transparently, making
  76. OPTIMA 96 exceptionally easy to use even though its feature set offers a
  77. wide range of capabilities and communications options.
  78.  
  79. Automode - Procedures defined in an appendix to CCITT Recommendation V.32
  80. that allow modems with both V.32 and V.22bis modulation to reliably
  81. interwork with other modems which have either or both of these
  82. modulations, at the highest speed in common between the modems.
  83.  
  84. Automatic Speed Buffering -  This enables the modem to communicate at
  85. varying speeds with other modems while communicating at a fixed interface
  86. speed if required by its attached DTE (mainframe, mini-computer, or PC).
  87.  
  88. Flow Control - Works with systems equipped with flow control to manage
  89. the interface between the modem and the system to control buffers and
  90. preserve data integrity, preventing inadvertent data loss between the
  91. modem and the system.
  92.  
  93. TRANSMISSION MODES
  94.  
  95. Asynchronous Hardware Mode - Supports standard asynchronous
  96. communications for dial-up communications with value added networks,
  97. on-line services, and personal computers.
  98.  
  99. Synchronous Hardware Mode - The modem supports SDLC, HDLC and Bisync
  100. synchronous transmission for connections to mainframes and mini-computers.
  101.  A PC using a synchronous adapter card is also supported.
  102.  
  103. Hayes AutoSync -  OPTIMA 96 can use the system's standard asynchronous
  104. communications port for synchronous communications, eliminating the
  105. additional expense of a synchronous adapter card for
  106. SDLC or Bisync.  This convenient feature brings both asynchronous and
  107. synchronous data transfer capability to your system in one communications
  108. device.
  109.  
  110. SERVICE AND SUPPORT
  111.  
  112. Technical Support -- Technical support for OPTIMA 96 is available through
  113. Hayes Customer Service in the U.S. at 404/441-1617 and in Canada at
  114. 416/283-2627.
  115.  
  116. Electronic Support -- Unlimited, free technical assistance is available
  117. electronically through Hayes Bulletin Board System at 404/HI MODEM or
  118. 800/US HAYES, as well as Hayes Forums on CompuServe and GEnie information
  119. services.
  120.  
  121. Product Warranty -- OPTIMA 96 holds a two year limited performance
  122. warranty.  If the product does not perform as stated in the manual, Hayes
  123. will repair or replace the product at no cost.  Hayes also offers an
  124. extended two year warranty for US$100 and CN$120.
  125. Smartcom EZ Communications Software
  126.  
  127. PROGRAM INTERFACE
  128.  
  129. On-Screen Menus - A simple menu interface logically groups program
  130. operations.  All menu items have "short-cut" keys that allow users to move
  131. quickly to the option they desire.  Function keys speed movement to other
  132. menus.
  133.  
  134. On-line Help System - A first time user is automatically provided with
  135. helpful information about how to start using the program right away.
  136. Smartcom EZ provides a comprehensive context-sensitive on-line help system
  137. that provides detailed information and cross-references to related topics.
  138.  From any point in the program, press the F1 key to access help.
  139.  
  140. Phone Book - Allows users to store frequently called phone numbers and
  141. other communications instructions to allow quick access to connecting and
  142. exchanging information.  New phone book entry automatically requests the
  143. phone number and other information without requiring the user to use the
  144. settings option and stores the information under a user definable name for
  145. future use.  Also provided are pre-entered phone book entries for the most
  146. popular information services such as MCI, AT&T, GEnie, CompuServe and US
  147. Sprint.
  148.  
  149. Direct Connect - Smartcom EZ provides a direct connect option that allows
  150. users to connect directly with a mainframe or minicomputer.  Also, this
  151. option can be used to issue AT Commands directly to the modem.
  152.  
  153. COMMUNICATIONS CONTROL AND AUTOMATION
  154.  
  155. Keyboard Macros - Users can assign a sequence of keys and entries to a
  156. specified key, reducing the number of key strokes and speeding up often
  157. used operations such as log-on sequences or information storable to a disk
  158. file.
  159.  
  160. MODEM CONTROL
  161.  
  162. Hayes Standard AT Command Set - Takes full advantage of the Hayes
  163. Standard AT Command Set for all Hayes Smartmodem products, including
  164. automatic selection of highest possible speed.  Default parameters are set
  165. to work in a majority of cases.  A user can also configure a modem through
  166. simple, on-screen selections which Smartcom EZ then translates into the
  167. appropriate commands that are issued to the modem.  Users can make maximum
  168. use of modem features without needing to learn AT Commands.  (Note:
  169. Direct connect is provided through Smartcom EZ for users who wish to issue
  170. AT Commands directly to the modem via the keyboard.)
  171.  
  172. Set-up String - Allows the selection of features of non-Hayes modems when
  173. those features are implemented using commands not found in the Hayes
  174. Standard AT Command Set.
  175.  
  176. TERMINAL EMULATION
  177.  
  178. VT102/100 - The program imitates the characteristics of the popular DEC
  179. VT102/100 terminal for communications with computers that recognize that
  180. terminal.  Provides support of VT102/100 keyboard functions, visual
  181. attributes and other key features.  The user guide provides suggestions
  182. for changes to settings if necessary based on possible variances in the
  183. remote system's requirements.
  184.  
  185. TTY (Teletypewriter) - A widely used type of emulation for PC computer
  186. communications.  This is available as a subset of the VT102
  187. implementations.
  188.  
  189. FILE TRANSFER PROTOCOL
  190.  
  191. XMODEM - This is a widely used file transfer protocol that is supported
  192. by most bulletin boards and on-line information services and is useful for
  193. the error-controlled transmission of files.
  194.  
  195. ON-LINE OPERATION
  196.  
  197. Printing - A user can concurrently print information as it is received.
  198.  
  199. Disk Capture - A user can also concurrently save information to disk as
  200. it is being received for later review.  This can help reduce the duration
  201. of costly on-line and telephone charges.
  202.  
  203. Autotyping - A quick way to send a text file to the remote system is to
  204. autotype it.  When autotyping a file, text is sent to the remote system as
  205. if a user were rapidly typing it.
  206.  
  207. SPECIFICATIONS
  208.  
  209. System Requirements - Requires an MS-DOS compatible computer with minimum
  210. of 512K RAM,
  211. MS-DOS( Version 2.0 and higher.
  212.  
  213. Printer Types - Serial and parallel types.
  214.  
  215. SERVICE AND SUPPORT
  216.  
  217. Product Warranty --  Smartcom EZ communications software holds a unique
  218. limited 90-day performance warranty.
  219.  
  220. Technical Support --  Technical support for Smartcom EZ is available
  221. through Hayes Customer Service in the United States at 404/441-1617, in
  222. Canada at 416/283-2627.
  223.  
  224. Electronic Support --  Unlimited, free technical assistance is available
  225. electronically through Hayes Bulletin Board System at 404/HI MODEM or
  226. 800/US HAYES, as well as Hayes Forums on CompuServe and GEnie information
  227. services.
  228.  
  229. Software Upgrade -- Smartcom EZ can be upgraded to Smartcom Exec for $35
  230. until October 31, 1991.  After this date, Smartcom EZ can be upgraded to
  231. Smartcom Exec for $55.  Smartcom Exec is a global communications software
  232. program that supports most DOS environments, including Windows as a full
  233. screen application and Desqview.  Smartcom Exec also features mouse
  234. support, keyboard macros, a peruse buffer, and a powerful text editor with
  235. word processing capabilities.  The powerful scripting language (SCOPE) is
  236. also provided to automate repetitive tasks.
  237.  
  238. Hayes, the Hayes logos and Smartcom EZ are registered trademarks, and
  239. Smartmodem and OPTIMA are trademarks of Hayes Microcomputer Products, Inc.
  240.  MNP is a registered trademark of Microcom, Inc.  The Consultative
  241. Committee on International Telegraphy and Telephony (CCITT), part of the
  242. International Telecommunications Union, is the United Nations agency
  243. responsible for development of standards for international data
  244. communications.
  245.  
  246. Other trademarks identified in this summary are trademarks of their
  247. respective companies.
  248.